Precautionary Maintenance Can Prolong Your Water Heater's Useful Life... Examine Yours Today!

Drag to rearrange sections
Rich Text Content
Your water heater is definitely probably the essential part00 of your houses plumbing system. A new properly maintained heating unit can last coming from ten to 15 years or additional. However a water heater not properly managed can fail throughout four to six years. The particular condition of the particular drinking water throughout your area along with the location of the heater in your home are out there of your control, but proper maintenance of the heating unit and your plumbing related system is important to heater long life and safety.

This article gives an individual a listing of items to check for both tank type and even tankless water emitters. As Water Heater Replacement Centennial Colorado go through the steps in looking at your heater, have got the slightest doubt in the ability, get some sort of professional, licensed local plumber involved! You are usually dealing with hot water, natural gas, in addition to electricity!

Tank Sort Hot water heater Maintenance:

Vent (Gas Water Heaters Only)

The in-take should be the particular same diameter as the draft diverter on the water heater tank.
The vent should go normally "up and out" the ceiling.
Wherever is passes by means of the exterior wall structure, the vent ought to be double-walled.
Vent out sections should become screwed together using a minimum 3 screws per segment.
Note: Bad vent out pipe connections can easily fall apart and even cause carbon monoxide poisoning, the silent and deadly gasoline!

Temperature & Stress Relief Valve (T&P Valve)The T&P valve is designed to be able to avoid the heater coming from exploding if the particular water pressure or temperature exceeds safe limits.

Chin up the particular handle for the device and water need to flow out and even stop when a person forget about the take care of.
The T&P regulators has a drain range which should go straight down to about 6" from the ground or be plumbed outside your house.
Note: Water seeping out of some sort of T&P drain collection can signal a poor T&P valve, large water pressure, or perhaps a malfunctioning thermal growth device.

Water Strain (All Water Heaters)

Water pressure above 80 pounds per square inch (psi) can damage emitters and your piping. This can also harm plumbing appliances, lavatories, and your accessories.
Note: One free item your have superior water pressure is usually once the T&P Regulators for the heater starts off buying and selling.

Outer Drinking water Heater Metal Shell & Plumbing Accessories

Inspect the heaters outer sheet steel shell for leakages or rusting.
Inspect the plumbing accessories on the heating unit for corrosion, corrosion, or water recognizing.
Note: Rusty furnishing or discolored layer is a distinguishing sign that a new leak is present!

Heat Control

Inspect typically the heater temperature management dial to ensure its set with the correct temperature of the water.
The ideal water temperature is 120� Fahrenheit.
Note: Anything at all above 120� Fahrenheit greatly increases scalding risk, energy employ, and sediment build-up in the underside of the heaters!

Combustion Chamber (Gas Water Heaters)

Turn the gas device control to "pilot position".
Remove typically the outer access emerge or cover upon the side involving the heater.
Check the roof with the chamber for large rusting, water marking, or pitting.
Return the gas device control back to be able to the "on position".
Note: Black soot in the combustion chamber means drafting difficulties, combustion problems, blow up problems, and a fire hazard!

Grada Base (Gas Drinking water Heaters)

Make sure the grada base the heater rests on is stable and supports the unit.
The particular typical pedestal will keep the base from the heater in least 18" off the floor.
Note: A more recent water heater may have the "filtered combustion chamber" that is intended to resolve the particular need for the pedestal. Check typically the owner's manual for your heater.

Empty Valve

Open typically the drain valve to insure that vitamin sediment, anode sludge, or rust has not clogged your emitters drain.
Drain Overflow Pan

If the heater is upon the 2nd floors above living space this should have the drain pan.
The particular drain pan need to be plumbed to the outside of your house.
Inspect typically the condition of the drain pan, furnishing, and piping towards the outside.
Corrosive Gases (Gas Water Heating units & Tankless Normal water Heaters)

Water emitters draw air in for combustion as well as the quality of typically the air is crucial.
Corrosive liquids, phosphate, or acids saved near a water heater can lead to be able to corrosive air.
Take note: Corrosive air drawn in the burner may prematurely corrode the particular heater.